Newtec AZ210 is a versatile 1+1 protection scheme for satellite modulators. The AZ210 is easy to operate and switches simultaneously the input data signals and output IF/RF signals. The switching between the main modulator and the redundant modulator can be done automatically through alarm contacts, manually through the front panel or the dedicated web interface, or remotely via a monitoring and control system.
Fully Automatic
When the automatic mode is activated, the AZ210 monitors the alarm contacts of the two modulators through cable connections. When an alarm is detected, the input and output switches are toggled, eff ectively rerouting the input and output signals to the redundant modulator. The fast switching ensures a minimal service interruption.
IF Switching
In its default confi guration, the AZ210 switches an output IF (75 ohms) signal. A wide range of input and output switching options makes the AZ210 compatible with almost any signal used in satellite communications. The range of options includes ASI, optical, G.703, SDH, HSSI input switches, as well as IF, L-band and RF output switches.
Built-In Monitoring
The AZ210 is easy to operate and monitor. All control and monitoring parameters are available locally on the front panel and remotely through a web interface. It is also possible to control or monitor the AZ210 via RMCP or SNMP.
Key features
• Dual redundant power supply
• Automatic or manual operational mode
• Suitable for any modulator with alarm contacts
• Switching of ASI, G.703, SDH or HSSI inputs
• Switching of IF, L-band or RF-band outputs
• Standalone operation or integrated in a network management system
Main advantages
• Increases service availability significantly
• Compatible with any modulator that has alarm contacts
• High reliability
• High compactness
• Easy to operate
Applications
• Satellite Broadcast
• Contribution and distribution
• DSNG
• Any uplink facility
Related products
AZ110 Broadcast Satellite Modulator
AZ119 ABS-S Satellite Modulator
AZ120 Telco Satellite Modulator
AZ128 High Speed Telco Satellite Modulator
AZ130 WAN Satellite Modulator
AZ200 Universal Switching system
AZ270 1+1 Frequency redundancy Switch
AZ290 1+1 Demodulator redundancy Switch
Input Interface switch
ASI/G.703
• Connectors 4 x BNC (F) - 75 ohms
• Frequency DC - 270 MHz
• Insertion loss < 2 dB
• Isolation > 50 dB (300 MHz)
Optical, SC, single mode
• Connector 2 x duplex SC receptacles
• Minimum input power -30dBm
• Minimum output power -15dBm
• Wavelength 1300 nm
• Compliancy SONET OC3 & SDH STM1 (S1.1)
Optical, SC, multi mode
• Connector 2 duplex SC receptacles
• Minimum input power -30dBm
• Minimum ouput power -23.5dBm
• Wavelength 1300 nm
• Compliancy ATM Forum UNI SONET OC-3 Multimode
Fiber Physical layer specifi cation
HSSI
• Connectors 25 pin sub-D (F)
• Frequency DC - 52 MHz
• Isolation > 30 dB (balanced)
Output interface switch
IF (75 ohms, DC - 270 MHz)
• Connectors BNC (F) - 75 ohms
• Frequency DC - 270 MHz
• Insertion loss < 2 dB
• Isolation > 50 dB (300 MHz)
IF (50 ohms, DC – 270 MHz)
• Connectors BNC (F) - 50 ohms
• Frequency DC - 270 MHz
• Insertion loss < 2 dB
• Isolation > 50 dB ( 300 MHz)
L-band (50 ohms, DC-2.5 GHz)
• Connectors BNC (F) - 50 Ohm
• Frequency DC - 2.5 GHz
• Return loss > 18 dB (L band)
• Insertion loss < 0.5 dB
• Isolation > 75 dB (L band)
L-band (50 ohms, DC-1.8 GHz)
• Connectors SMA - 50 ohms
• Frequency DC - 1.8 GHz
• Return loss > 15 dB
• Insertion loss < 2 dB
• Isolation > 50 dB
L-band (50 ohms, DC – 18 GHz)
• Connectors SMA (F) - 50 Ohm
• Frequency DC - 18 GHz
• Return loss > 18 dB (L band) >13 dB (RF)
• Insertion loss < 0.5 dB
• Isolation > 75 dB (L band) >60 dB (RF)
Generic
Monitor and control interfaces
• Web based GUI
• Diagnostics report, alarm log
• RMCP over TCP-IP/UDP and RS232/RS485
• SNMP v2c
Physical
• 1RU, width: 19”, depth 51 cm, 6 kg
• Dual Power supply: 100-240 VAC, 105 VA, 47-63 Hz
• Temperature
- Operational: 0°C to 37°C
- Storage: -40 to +70°C
• Humidity: 5% to 85% non-condensing
• CE label, UL label
• Satellite Broadcast
• Contribution and distribution
• DSNG
• Any uplink facility