Comtech EF Data ODM-840 Advanced VSAT Solutions Remote IP Receiver Router

CTOG-250

Comtech EF Data CTOG-250 Advanced VSAT Solutions Traffic Optimization Gateway

Comtech SPOD

Comtech EF Data SPOD High Power Outdoor SSPA Series Amplifier Systems

SKU
ODM-840
Comtech EF Data ODM-840 Advanced VSAT Solutions Remote IP Receiver Router is available to buy in increments of 1

Rugged weatherized construction for outdoor use, Ideal for mobile backhaul applications, Integrated router with RAN Optimization

ODM-840 Advanced VSAT Solutions Remote IP Receiver Router

Comtech EF Data’s Advanced VSAT Solutions portfolio provides high-performance satellitebased communication solutions for a diverse range of applications, including broadband maritime, offshore communications, mobile backhaul with RAN optimization, IP trunking and backhaul, corporate and enterprise networks, emergency and disaster recovery.
Incorporating advanced technologies developed by Comtech EF Data, AHA Products Group, Memotec and Stampede, the solutions provide unmatched performance, industryleading bandwidth efficiencies and network optimization – while minimizing Total Cost of Ownership.

Designed for use at remote sites, the Comtech CEFD ODM-840 Remote Router combines a wide range of advanced technologies in an outdoor, rugged package, eliminating the need for shelter and/or air conditioning.

The products enable the most efficient bandwidth utilization for hub-spoke networks:

High-performance packet processing
Lossless Payload compression
Header compression
Advanced Quality of Service (QoS)
Dynamic SCPC with VMS
DVB-S2 and VersaFEC® low-latency LDPC Forward Error Correction
Ultra low overhead encapsulation
E1 RAN Optimization (ODM-840 only)

Features

Outdoor package

Extended operating temperature: ODM-840: -40° to +55°C, ODMR-840 (-20°to +55°C)

High-Performance Integrated Packet Processing

Layer 3 (Routed) operation
Advanced Quality of Service (QoS)
Header compression
Lossless payload compression
Ultra low overhead Streamline Encapsulation (TX)

Low overhead Enhanced Generic Stream Encapsulation (GSE) (RX)

Integrated E1 RAN optimization (ODM-840 only)
Simultaneous IP/Ethernet and E1 operation (ODM-840 only)

Advanced Forward Error Correction

VersaFEC low-latency LDPC transmit
DVB-S2 receive

Adaptive Coding and Modulation (ACM) capable transmit and receive

Variable Coding and Modulation (VCM) capable receive Transmit

Data rate: 16 kbps to 15.35 Mbps

Symbol rate: 16 ksps to 4.5 Msps

Modulation: BPSK, QPSK, 8-QAM, 16-QAM

Rolloff : 20%, 25%, 35%

Ultra low overhead Streamline Encapsulation

Receive

Frequency: 950 to 2150 MHz
Data rate: 1 Mbps to 160 Mbps
Symbol rate: 1 Msps to 62 Msps
Rolloff : 20%, 25%, 35%
Demodulation: QPSK, 8PSK, 16APSK, 32APSK
Low overhead enhanced Generic Stream Encapsulation
Operating Frequency: 950 to 2150 MHz

Traffic interfaces

10/100/1000Base-T Ethernet
G.703 E1 (ODM-840 only)

Management interface

10/100Base-T Ethernet for web and SNMP
Integrated with NetVue Integrated Management System and Vipersat Management System
BUC support (ODM-840 only)
LNB support
1:1 redundancy (ODM-840 only)

Transmit

Data Rate

16 kbps to 15.35 Mbps, in 1 bps step (CCM mode) (Modulation and FEC dependent)

Symbol Rate

16 ksps – 4.5 Msps (CCM mode)

FEC

VersaFEC Encoder (ACM and CCM modes)


Modulation & Code Rate


Data Rate Range

BPSK 0.488

16.00 kbps – 2.19 Mbps

QPSK 0.533

17.07 kbps – 4.80 Mbps

QPSK 0.631

20.19 kbps – 5.67 Mbps

QPSK 0.706

22.577 kbps – 6.34 Mbps

QPSK 0.803

25.69 kbps – 7.22 Mbps

8-QAM 0.642

30.83 kbps – 8.67 Mbps

8-QAM 0.711

34.14 kbps – 9.60 Mbps

8-QAM 0.780

37.44 kbps – 10.53 Mbps

16-QAM 0.731

46.80 kbps – 13.16 Mbps

16-QAM 0.780

49.92 kbps – 14.04 Mbps

16-QAM 0.829

53.04 kbps – 14.91 Mbps

16-QAM 0.853

54.60 kbps – 15.35 Mbps

Encapsulation

Ultra low overhead Streamline Encapsulation


Receive

Receive Data Rate (Pilots Off)

QPSK: 1.000 – 110.893 Mbps
8-PSK: 1.779 – 166.110 Mbps
16-APSK: 2.637 – 167.665 Mbps
32-APSK: 3.703 – 168.000 Mbps

Receive Symbol Rate

QPSK: 1 to 62 Msps
8-PSK: 1 to 62 Msps
16-APSK: 1 to 47 Msps
32-APSK: 1 to 37 Msps

FEC

DVB-S2 Decoder (ACM, CCM and VCM modes) Normal frame


Modulation & FEC


Data Rate Range
(Normal FEC frame, pilots off)

QPSK 1/4

1.000 – 30.395 Mbps

QPSK 1/3

1.000 – 40.699 Mbps

QPSK 2/5

1.000 – 48.943 Mbps

QPSK 1/2

1.000 – 61.309 Mbps

QPSK 3/5

1.188 – 73.674 Mbps

QPSK 2/3

1.322 – 81.979 Mbps

QPSK 3/4

1.487 – 92.223 Mbps

QPSK 4/5

1.587 – 98.406 Mbps

QPSK 5/6

1.654 – 102.589 Mbps

QPSK 8/9

1.766 – 109.519 Mbps

QPSK 9/10

1.788 – 110.893 Mbps

8-PSK 3/5

1.779 – 110.359 Mbps

8-PSK 2/3

1.980 – 122.799 Mbps

8-PSK 3/4

2.228 – 138.143 Mbps

8-PSK 5/6

2.478 – 153.670 Mbps

8-PSK 8/9

2.646 – 164.052 Mbps

8-PSK 9/10

2.679 – 166.110 Mbps

16-APSK 2/3

2.637 – 123.948 Mbps

16-APSK 3/4

2.966 – 139.436 Mbps

16-APSK 4/5

3.165 – 148.784 Mbps

16-APSK 5/6

3.300 – 155.108 Mbps

16-APSK 8/9

3.523 – 165.587 Mbps

16-APSK 9/10

3.567 – 167.665 Mbps

32-APSK 3/4

3.703 – 168.000 Mbps

32-APSK 4/5

3.951 – 168.000 Mbps

32-APSK 5/6

4.119 – 168.000 Mbps

32-APSK 8/9

4.397 – 168.000 Mbps

32-APSK 9/10

4.453 – 168.000 Mbps

Pilots

On/off, automatically detected

Encapsulation

Low overhead Enhanced GSE


Modulator

Operating Frequency

950 to 2150 MHz L-Band,
100 Hz frequency resolution

Frequency Stability

± 0.06 ppm (± 6 x 10-8), 0° to 50°C (32° to 122° F)

Frequency Reference

Internal

Scrambling

Comtech, disabled

Spectral Inversion

Normal or inverted

Transmit Filtering

Per IESS-308/-309 spectral mask

Transmit Filter Rolloff (Alpha)

20%, 25% and 35%

Output Power

0 to -40 dBm, in 0.1 dB steps

Power Accuracy

± 1.0 dB over frequency, data rate, modulation type and temperature range of 0 to 50° C

Transmit On/Off Ratio

-60 dBc minimum

Harmonics and Spurious

Better than -60 dBc/4 kHz
(typically < -65 dBc/4KHz)
Measured from Fo +/- 300 MHz

Output Phase Noise
    @ 100 Hz
    @ 1 kHz
    @ 10 kHz
    @ 100 kHz


-66.0 dB/Hz
-76.0 dB/Hz
-86.0 dB/Hz
-96.0 dB/Hz

< 1º rms double sided, 100 Hz to 1MHz (minimum of 6 dB better overall than the Intelsat IESS-308/309 requirement)

Fundamental AC line spurious is -42 dBc or lower The sum of all other single sideband spurious, from 0 to 0.75 x symbol rate, is -48 dBc or lower

Connector

Type N (female)

Impedance

50 Ω

Return Loss

20 dB, minimum

External TX Carrier Off

By TTL ‘low’ signal

Test Modes

CW, 1/0 pattern, 2^23-1 and 2047 patterns

BUC Reference (10 MHz)

Via TX IF center conductor, 10.0 MHz ± 0.06 ppm, selectable on/off, 0.0 dBm ± 3 dB

BUC Power Supply (HW Option)

24 VDC, 4.17 Amps max., 90 W @ 50° C
48 VDC, 3.125 Amps max., 150 W @ 50° C
Supplied through TX IF center conductor and selectable on/off via M&C control


Demodulator Specifications

Operating Frequency

950 to 2150 MHz L-Band, 100 Hz frequency resolution

Connector

Type N (female)

Impedance

50 Ω

Input Power Range, Desired Carrier

-65 dBm + 10 log (symbol rate in MHz) to -25 dBm

Maximum Composite Operating Level

-5 dBm total composite power
20 dBc within 10 MHz band from the desired carrier for QPSK, 8-PSK, and 16-APSK
10 dBc within 10 MHz band from the desired carrier for 32-APSK
30 dBc outside of 10 MHz from carrier

Absolute Maximum, No Damage

-10 dBm

Rolloff

20%, 25%, 35%

Acquisition Range

+/- 100 kHz

Adaptive Equalizer

Corrects up to 3 dB tilt

Return Loss

12 dB, minimum (typical 15 dB)

LNB Reference (10 MHz)

Via RX IF center conductor, 10.0 MHz ± 0.06 ppm
Selectable on/off, -3.0 dBm ± 3 dB

LNB Voltage

Selectable on/off, 13 VDC, 18 VDC, 24 VDC

LNB Current

500 mA, maximum

Monitor Functions

Es/No estimate, receive signal level, frequency offset

Es/No Monitor Accuracy

+/- 0.3 dB

Receiver Signal Level Monitor Accuracy

+/- 6 dB (typical)


Packet Processor

Supported Protocols

 

RFC 768 – UDP
RFC 791 – IP
RFC 792 – ICMP
RFC 793 – TCP
RFC 826 – ARP
RFC 856 – Telnet
RFC 862 – Ping
RFC 894 – IP
RFC 959 – FTP
RFC 1112 – IP Multicast
RFC 1213 – SNMP MIB II

RFC 1812 – IPv4 Routers
RFC 2045 – MIME
RFC 2474 – Diffserv
RFC 2475 – Diffserv
RFC 2578 – SMI
RFC 2597 – AF PHB
RFC 2598 – Expedite Forwarding
RFC 2616 – HTTP
RFC 3412 – SNMP
RFC 3416 – SNMPv2
RFC 3418 – SNMP MIB

Statistics

Detailed packet and throughput stats


Connectors

L-Band Transmit and Receive

2 x N-type (female)

10/100Base-T Ethernet interface

RJ-45

G.703 E1, 2.048 Mbps (Unbalanced 75 Ω)

BNC (female)

Console / Redundancy Interface

19-pin circular connector


Available Options

Option

Type

-48 VDC, Primary Power Supply

Hardware

24 VDC, 90 W @ 50° C BUC Power Supply

Hardware

48 VDC, 150 W @ 50° C BUC Power Supply

Hardware

Extended (Low) Temperature Version

Hardware

Transmit Data Rate

FAST

Receive Data Rate

FAST

Lossless Payload Compression /
Decompression

FAST

Header Compression/Decompression

FAST

Advanced Quality of Service

FAST

E1 RAN Optimization

FAST

G.703 Clock Extension

FAST

Physical, Power & Environmental

   

Dimensions (1RU) (H x W x D)

9’’ x 5.5’’ x 16.75’’
(22.7 x 13.9 x 42.2 cm) approximate

Weight

22 lbs

Power Supply

100-240 VAC, 47Hz-63Hz 
-48 VDC (HW option)

Ingress Protection Rating

IP67

Operating Temperature

0° to 55°C 
-40° to 55° C (Extended Temperature Version, HW option)

Storage temperature

–40° to 70°C

Accessories

Mounting Kit

 

Regulatory

CE Mark

EN55022 Class B (Emissions)
EN50082-1 Part 1 (Immunity)
EN60950 (Safety)

FCC Approval

FCC Part 15 Class B

ODM-840 specifications

Comtech ODM-840 specs page 2

Comtech ODM-840 specs page 3

Typical Users

Offshore & Maritime

Mobile Operators

Telecom Operators

Enterprise

Internet Service Providers (ISPs)


Common Applications

Maritime & Offshore Communications

Mobile Backhaul with RAN Optimization

IP Trunking & Internet Access