Wavestream Gilat Ku-Band Matchbox Mini Block Upconverter 16W / 25W / 40W
Smallest 40W BUC Available on the Market, Low Power Draw, High MTBF, Flexible, Modular Feed-Mount Design
Matchbox Mini BUC
Wavestream’s Ku-band Matchbox Mini Block Upconverter (BUC) offers unmatched efficiency and performance suitable for mobile SATCOM, flyaway and VSAT systems. The Ku-band Matchbox Mini BUC incorporates Wavestream’s next generation Spatial advantEdge technology to provide higher output power in smaller, lighter weight packages that are more reliable and use less energy. The Ku-band Matchbox Mini is the smallest 40W P1db BUC on the market today and is field proven to withstand the most extreme environments. Every unit is thoroughly tested to guarantee performance over the full frequency band and
over the full temperature range.
Highly Efficient
Wavestream products are biased for Class AB operation, drawing less power when backed off to help save valuable energy resources. They generate less heat, ensuring a higher MTBF (Mean Time Between Failures) for greater reliability and lower lifecycle costs.
Redundant Configuration
Optional 1:1 Redundancy Kits are available to provide an integrated solution for uninterrupted, reliable satellite transmissions. The 1:1 Redundancy Kit integrates the waveguide, switch and mounting hardware, and offers ease of installation and subsequent maintenance to accommodate outdoor mounts.
Configurations
The Ultra Mini Wavestream Matchbox BUCs are available in three RF power output configurations:
16 Watt
25 Watt
40 Watt
RF Specifications 16W 25W 40W
Transmit Frequency
Standard
Extended Band Option
14.0 - 14.5 GHz
13.75 - 14.5 GHz
14.0 - 14.5 GHz
13.75 - 14.5 GHz
14.0 - 14.5 GHz
13.75 - 14.5 GHz
IF Frequency
- Standard
- Extended Band Option
950 - 1450 MHz
950 - 1700 MHz
950 - 1450 MHz
950 - 1700 MHz
950 - 1450 MHz
950 - 1700 MHz
Frequency Reference
(10 MHz on IF)
0 dBm ± 5 dB 0 dBm ± 5 dB 0 dBm ± 5 dB
Small Signal Gain 70 dB nominal 70 dB nominal 70 dB nominal
Gain Adjustment 20 dB, 2 dB steps nominal 20 dB, 2 dB steps nominal 20 dB, 2 dB steps nominal
Gain Variation
(over frequency at fixed temperature)
0.5 dB over 36 MHz
3 dB over 500 MHz
0.5 dB over 36 MHz
3 dB over 500 MHz
0.5 dB over 36 MHz
3 dB over 500 MHz
Gain Variation
(over temperature at fixed frequency)
3 dB p-p over operating range 3 dB p-p over operating range 3 dB p-p over operating range
Saturated Output Power 42.5 dBm (nominal) 44.5 dBm (nominal) 46.5 dBm (nominal)
P1dB Output Power * >42 dBm >44 dBm >46 dBm
Rated Output Power * 42 dBm 44 dBm 46 dBm
Intermodulation *
(Third order intermodulation product relative to combined power of two carriers at 3 dB total power back-off from Rated Output Power)
-25 dBc -25 dBc -25 dBc
Spectral Regrowth
(For QPSK at 1.5x and for OQPSK at 1.0x symbol rate offset at 2 dB backoff from Rated Output Power)
-30 dBc -30 dBc -30 dBc
Phase Noise Meets IESS-308 Meets IESS-308 Meets IESS-308
AM/PM Conversion
(up to 2 dB below Rated Output Power)
2 deg/dB 2 deg/dB 2 deg/dB
Noise Power Density - Transmit -70 dBW/4 kHz (maximum) -70 dBW/4 kHz (maximum) -70 dBW/4 kHz (maximum)
Noise Power Density - Receive -150 dBW/4 kHz (maximum) -150 dBW/4 kHz (maximum) -150 dBW/4 kHz (maximum)
Output Spurious -60 dBc -60 dBc -60 dBc
Interfaces 16W 25W 40W
IF Port Connector Type N Female Type N Female Type N Female
IF Input Impedance 50 ohms 50 ohms 50 ohms
IF Input VSWR 2:1 maximum 2:1 maximum 2:1 maximum
RF Output Connector WR-75 WR-75 WR-75
RF Output VSWR 1.25:1 maximum 1.25:1 maximum 1.25:1 maximum
DC Connector and Monitor &
Control Connector
12-Pin Military Circular 12-Pin Military Circular 12-Pin Military Circular
Monitor & Control Serial RS-485 (SA-bus), Forward
Power Monitor, Step Attenuator
Serial RS-485 (SA-bus), Forward
Power Monitor, Step Attenuator
Serial RS-485 (SA-bus), Forward
Power Monitor, Step Attenuator
LED Indicators Summary Fault, Loss of Lock Summary Fault, Loss of Lock Summary Fault, Loss of Lock
Physical
Size 8.9”L x 5.4”W x 4.2”H 8.9”L x 5.4”W x 4.2”H 8.9” L x 5.4”W x 4.2”H
Weight 7.8 lbs 7.8 lbs 7.8 lbs
Operating Temperature
(Ambient Air)
-40°C to +60°C -40°C to +60°C -40°C to +60°C
Relative Humidity 100% Condensing
Shock & Vibration Designed to withstand 20G at 11 ms ½ sine wave non-operating conditions, and MIL-STD-810E,
method 514-4 transportation vibration
Altitude 10,000 ft above sea level (operating)
Options
External Power Supply, AC/DC Converter, 100-240 VAC; DC Power - IFL Option (48V only at 40W)
Monitor & Control - Ethernet; RS-232
1:1 Redundancy Kit - to include waveguide, switch, cable connectors, and mounting hardware
Rack Mount Controller - 1U rack mount chassis to control any Wavestream amplifier in a 1:1 configuration with LCD display and
key status LEDs
Indoor to outdoor cable assemblies - available in 25’, 50’ and 100’ lengths.
Higher output power with less energy usage, Compact product footprint to meet critical space and weight limitations, Proven reliability and efficiency, Reduced lifecycle maintenance costs.